PORT
ENGINE
STBD
ENGINE
ICON HUB WITH
INTERNAL
TERMINATION
(764943
Figure 5-1. Evinrude ICON-CAN2 interconnection, single station, twin engine.
5-2
Use crimped Molex Perma-Seal (or equivalent) butt splice connectors,
or shrink-sealed solder connections. Locate all splices in a dry location
and secure them properly against mechanical damage.
Supplied with the Evinrude system is an accessory relay that provides
power to the CAN network when the key switch is in the accessory
position. It normally plugs into the ICON hub but in some cases you
will need to remove it to connect the CAN2 network. In this case
you will need to buy the adapter harness CM20017 to connect the
relay to an Optimus network tee.
Figure 5-1 and 5-2 illustrate the network interconnection for single
and dual station applications. All adapter harnesses are identified
in the figures.
IGNITION
CM204XX
CM20406
PCM
HELM 1
CM20304
CERTIFIED
AUTOPILOT
(OPTIONAL)
ACC RELAY
(EVINRUDE)
Note: Aft-mounted PCM shown. If PCM is mounted forward you can
connect CM20304 directly to a CAN2 tee.
© 2014 SeaStar Solutions
PURPLE
COLOR
CONTROL
JOYSTICK 1
CANtrak 1
HEAD 1
CM21504
BUZZER
CM20016
ICON HUB WITH
INTERNAL
TERMINATION
(764943
Optimus 360 Installation Supplement, Rev. B
RUN
OFF
EXTENSION
CABLE (if Req.)
See ICON guide
EST GATEWAY
(by EVINRUDE)
EVINRUDE EST-CAN
OPTIMUS CAN1
OPTIMUS CAN2
CM20016 ADAPTER
CM20021 ADAPTER
CH TO KEY SWITCH
FUSE
+
TO ENGINE
BATTERY
(use Evinrude
harness
764921)
TO NMEA 2000
PUBLIC NETWORK

Hide quick links: