Application Macros

Application Macros are preprogrammed parameter sets. They minimise the number of different
parameters to be set during start-up. The Factory Macro is the factory-set default macro.
Note! The Factory Macro is intended for applications where there is NO control panel available. It
should not be used when control panel is in use, because macro dependent parameters cannot be
set. With other macros the control panel is needed.
Parameter Values
Selecting an application macro with parameter 9902
will set all other parameters
APPLIC MACRO
(except the group 99 Start-up Data parameters, the parameter lock 1602 and groups 50 - 52 serial
communication parameters) to their default values.
Default values of certain parameters depend on the selected macro. These are listed with the
description of each macro. Default values for other parameters are given in "ACS 400 Complete
Parameter List" starting on page 55.
Connection Examples
In the following connection examples please note:
All the digital inputs are connected using negative (NPN) logic.
ACS 400 User's Manual