PROGRAMMING

ACS-PAN-A Control Panel

ACS-PAN-A is an alphanumeric control panel with LCD display and multiple languages. The control
panel can be connected to and detached from the converter at any time. The panel can be used to
copy parameters to other ACS 400 converters with the same software revision (parameter 3301).

Control modes

Display modes
MENU
Green LED
Red LED
RESET
Control Modes
The very first time the drive is powered up, it is controlled from the Control Terminal Block X1 (remote
control, REM). The ACS 400 is controlled from the control panel when the drive is in local control
(LOC).
Switch to local control (LOC) by pressing and holding the LOC/REM button until first LOCAL
CONTROL or later LOCAL, KEEP RUN is displayed:
If the button is released while LOCAL CONTROL is displayed, the panel frequency reference is
set to the current external reference and the drive is stopped.
When LOCAL, KEEP RUN is displayed, the current run/stop status and the frequency reference
are copied from the user I/O.
Start and stop the drive by pressing the START/STOP button.
Change the shaft direction by pressing the REVERSE button (parameter 1003 must be set to
).
REQUEST
Switch back to remote control (REM) by pressing and holding the LOC/REM button until REMOTE
CONTROL is displayed.
Shaft Direction
RUN >
< RUN
RUN > (or < RUN) Arrow head blinking rapidly
> (or <) Arrow head blinking slowly
ACS 400 User's Manual
OUTPUT MENU LOC REM RUN
MENU
ENTER
LOC
RESET
REM
REVERSE
LOC/REM
• Drive is running and at setpoint
• Shaft direction is forward (>) or reverse (<)
Drive is running but not at setpoint.
Drive is stopped.
Run indicator
Shaft direction
UP/DOWN
ENTER
START/STOP
29