Verilink DIDCSU 2912 Manual page 91

Dual integrated data service unit/channel service unit
Table of Contents

Advertisement

Figure 4-12 Data Port Diagnostics Menu
--
--
DIDCSU 2912 DATA PORT DIAGNOSTICS MENU --
DIDCSU 2912 DATA PORT DIAGNOSTICS MENU --
--
--
DIDCSU 2912 DATA PORT DIAGNOSTICS MENU --
DIDCSU 2912 DATA PORT DIAGNOSTICS MENU --
Cable
Cable
Cable
Cable
DPL Loopback
DPL Loopback
DPL Loopback
DPL Loopback
Test Pattern
Test Pattern
Test Pattern
Test Pattern
Test Error Counter
Test Error Counter
Test Error Counter
Test Error Counter
Dn) Data Port Loop
Dn) Data Port Loop
Dn) Data Port Loop
Dn) Data Port Loop
Fn) Send RDL Loop Code
Fn) Send RDL Loop Code
Fn) Send RDL Loop Code
Fn) Send RDL Loop Code
X) exit this screen
X) exit this screen
X) exit this screen
X) exit this screen
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
A [0.0.0.204] [1,2] DIDCSU 2912 >
Table 4-9
Data Port Diagnostics Menu Parameters
Command
Dn
Data Port Loopback (DPL): This option tests the channels assigned to the
data port (not the entire E1 bandwidth). The remaining channels, using
the circuit builder function, are not affected. This is a bi-directional loop
(toward the DTE and network).
Fn
Sends an industry standard CCITT Rdl loop request code toward the far
end DSU. This should result in a loopback affecting only those timeslots
assigned through the
Tn
Test Pattern: Use this option to select one of the following test patterns.
Note that patterns are always transmitted toward the net, not the DTE:
• None: This option indicates that no test pattern will be used. Note that
applies only to channels mapped to the net port, not the whole net.
• QRSS: Use Quasi-Random Signal Sequence that limits the signal to a
maximum of 15 zeros that can be transmitted sequentially. These
signals contain a medley of 20-bit words (except for more than 15
consecutive 0s). It repeats every 1,048,575 bits. Also, it contains high
density sequences and low density sequences, and sequences that
change from low density to high density and vice versa (as defined by
ANSI T1.403).
En
Reset Test Counter: Use this option to reset the error counter back to 0.
At the start of a test, this counter is automatically reset.
Data Port Diagnostics Menu
X
Exit the
Data Port 1
Data Port 1
Data Port 1
Data Port 1
PRESENT
PRESENT
PRESENT
PRESENT
DISABLE
DISABLE
DISABLE
DISABLE
NONE
NONE
NONE
NONE
0
0
0
0
Tn) Test Pattern
Tn) Test Pattern
Tn) Test Pattern
Tn) Test Pattern
En) Reset Test Counter
En) Reset Test Counter
En) Reset Test Counter
En) Reset Test Counter
Description
Circuit Build Menu
to this data port.
.
Verilink DIDCSU 2912 User Manual
DIDCSU E1 Version
Data Port 2
Data Port 2
Data Port 2
Data Port 2
PRESENT
PRESENT
PRESENT
PRESENT
DISABLE
DISABLE
DISABLE
DISABLE
NONE
NONE
NONE
NONE
0
0
0
0
1) DEACTIVATE
2) ACTIVATE
1)LOOP DOWN
2)LOOP UP
1) NONE
2) QRSS
Options
4-19

Advertisement

Table of Contents
loading

Table of Contents