Connect To Craft Port; Terminal Parameters; Logging On - Verilink DIDCSU 2912 Manual

Dual integrated data service unit/channel service unit
Table of Contents

Advertisement

DIDCSU 2912 Quick Set-Up
Connect to Craft
Port
Terminal
Parameters

Logging On

2-12
NOTE: These procedures may not match your configuration. Use this
chapter as a guide for equipment installation. Chapter 4,
"DIDCSU E1 Version"
the E1 mode.
Connect the modular (RJ-11) end of the Craft cable (P/N 458-
102119-008) to the port labeled
controller module. Connect the other end of the Craft cable to your
PC or terminal.
Set your terminal, or terminal program to:
• 19.2 kbit/s
• 8 data bits
• no parity
• one stop bit
• no flow control
1. Press E
. The pSH+> prompt is displayed. Type "craft".
NTER
2. A password prompt appears. Initially there is no password,
press E
to display the NCM Main Menu.
NTER
If the NCM Main Menu display
the proper shelf/slot position (letter A in slot 2), go to
Verilink DIDCSU 2912 User Manual
has complete details on configuration of
on the front panel of the NCM
LOCAL
(Figure 2-15)
shows the DIDCSU in
Step
10.