Verilink DIDCSU 2912 Manual page 52

Dual integrated data service unit/channel service unit
Table of Contents

Advertisement

DIDCSU T1 Version
Table 3-6
Configuration Menu (Timing Options) Parameters
Command
R
Receive Clock from Shelf: Use this option to indicate the DIDCSU
receives its timing signal from another card in the shelf, or from an on-
board timing source.
Note: Changing this option toggles between the shelf timing and
card timing menus.
PS
Primary Synchronization: Choose one of the following as your primary
source for clock synchronization.
• Net 1: T1 Port 1
• Net 2: T1 Port 2
• External: External clock
• Internal: Internal clock
• Data 1: Data Port 1 TT input signal
• Data 2: Data Port 2 TT input signal
SS
Secondary Synchronization: Use this option to specify an alternate
source of timing for synchronization. If the primary source is
unavailable, this source is used.
• Net 1: T1 Port 1
• Net 2: T1 Port 2
• External: External clock
• Internal: Internal clock
• Data 1: Data Port 1 TT input signal
• Data 2: Data Port 2 TT input signal
TS
Tertiary Synchronization: Use this option to specify an alternate source
of timing for synchronization. If the primary and secondary source are
unavailable, this source is used.
• Net 1: T1 Port 1
• Net 2: T1 Port 2
• External: External clock
• Internal: Internal clock
• Data 1: Data Port 1 TT input signal
• Data 2: Data Port 2 TT input signal
PA
Primary Auto Restore: Select Yes to resynchronize to the clock source
automatically if a previously failed clock source becomes available
again. Otherwise, choose No. Setting up auto restore returns timing to a
higher priority source after a failure clears.
3-12
Description
Verilink DIDCSU 2912 User Manual
Options
Yes or No
(Y/N)
1) NET 1
2) NET 2
3) EXTERNAL
4) INTERNAL
5) DATA 1
6) DATA 2
1) NET 1
2) NET 2
3) EXTERNAL
4) INTERNAL
5) DATA 1
6) DATA 2
1) NET 1
2) NET 2
3) EXTERNAL
4) INTERNAL
5) DATA 1
6) DATA 2
Yes or No
(Y/N)

Advertisement

Table of Contents
loading

Table of Contents