Lexmark C792 series Service Manual page 672

Hide thumbs Also See for C792 series:
Table of Contents

Advertisement

5062
Cable location table
P/N
item number
40X7168
10J0927
10J0929
10J0933
10J0935
10J0936
7-56
Service Manual
Description
Location
Paper path
Deflector assembly
cables
• System board connector:
JPP2
MPF sensor
Multipurpose feeder
cable
• System board connector:
JMPF1
Autocomp
Behind Tray 1, between MPF
W2W cable
redrive gears and rear frame
• System board connector:
JTRAY1
Duplex motor
Left access door
cable
• System board connector:
JDUPL1
Staging motor
Left access door
cable
System board connector:
JSTAG1
To access
1. Remove the lower frame cable
cover. See
"Lower frame cable
cover removal" on page
2. Remove the staging deflector
assembly. See
"Staging
deflector assembly removal"
on page
4-140.
3. Remove the LVPS to route the
cable through the hole in the
lower frame. See
"Low-voltage
power supply (LVPS) removal"
on page
4-86.
1. Remove the MPF sensor plate
assembly. See
"MPF sensor
plate assembly removal" on
page
4-108.
2. Remove the LVPS exit duct to
route the cable through the hole
in the lower frame. See
"LVPS
exit duct removal" on
page
4-89.
See
"MPF drive assembly
removal" on page
4-106.
See
"Staging paper path
reference edge assembly
removal" on page
4-142.
See
"Staging paper path
reference edge assembly
removal" on page
4-142.
Note: Use a cable tie to attach the
toroid to the new cable and frame
bracket.