173.xx—Blower fan error service check
Step
Questions / actions
1
Turn the printer off, and open the system
board shield. Check the cable in connector
JBLW1 (blower & right side waste cable) for
proper connection to the system board.
Is the cable properly connected?
2
Check the cable in the connector JBLW1
(blower & right side waste cable) for damage.
Is the cable damaged?
3
Remove the cartridge blower assembly. See
"Cartridge blower assembly removal" on
page
4-39.
Check the cable (B) connected to the
assembly.
Is the cable connected to the blower fan?
4
Replace the cartridge blower assembly. See
"Cartridge blower assembly removal" on
page
4-39.
Does the error reoccur?
Yes
Go to step 2.
Replace the blower & right
side waste cable. See
"Printhead access cover
removal" on page 4-19
access the cable on top of
the frame.
Go to step 4.
B
Replace the system board.
See
"System board
removal" on page
No
Reseat the cable.
Go to step 3.
to
Reseat the cable.
Problem solved.
4-151.