Flange Back Adjustment (Pal (50I) Mode); Flange Back Check (Pal (50I) Mode) - Sony HVR-Z1J Service Manual

Digital video camera recorder
Hide thumbs Also See for HVR-Z1J:
Table of Contents

Advertisement

11. Flange Back Adjustment (PAL (50i) mode)

Copy the adjustment data of NTSC (60i) mode.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: This adjustment should be carried out upon completion of the
NTSC (60i) mode adjustments.
Note2: This adjustment should be carried out upon completion of the
following adjustments of PAL (50i) mode.
"HALL Adjustment", "MR Adjustment"
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
NTSC (60i)/PAL (50i) ............................................ PAL (50i)
Adjusting method:
Order Page Address Data
1
0
01
2
6
D0
3
6
D1
4
6
D2
5
6
01
6
6
02
7
6
01
8
6
D0
9
6
D1
10
6
D2
11
6
01
12
6
02
5
F
6F
Note5: The adjustment data will be automatically input to page: F, address:
60 to 70, F4.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
0
01
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
Not required
Adjustment remote commander
F
60 to 70, F4
Data of page: F, address: 6F is "00" to
"0E".
Procedure
01
Set the data.
0F
Set the data.
60
Set the data.
11
Set the data.
FB
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note5)
00
Set the data, and press PAUSE
button.
0F
Set the data.
F4
Set the data.
01
Set the data.
FB
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note5)
Check that the data is "00" to
"0E".
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.

12. Flange Back Check (PAL (50i) mode)

Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: The data of page: 0, address: 10 must be "00".
Switch setting:
1)
NTSC (60i)/PAL (50i) ............................................ PAL (50i)
2)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
3)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Shoot the Siemens star with the zoom TELE end.
4)
Set the FOCUS switch to AUTO.
5)
Check that the lens is focused.
6)
Set the FOCUS switch to MANUAL.
9)
Change the zoom to the WIDE side from the TELE side, and
observe the TV monitor and check that the lens is focused.
6-34
Siemens star
(2.0m from the front of the lens)
(Luminance: 300 ± 50 lux)
Check operation on TV monitor
Focused at the TELE end and WIDE
end.