Color Reproduction Adjustment; (Ntsc (60I) & Pal (50I) Modes); Color Reproduction Adjustment Nd Off - Sony HVR-Z1J Service Manual

Digital video camera recorder
Hide thumbs Also See for HVR-Z1J:
Table of Contents

Advertisement

Ver. 1.7 2007. 10

18. Color Reproduction Adjustment

(NTSC (60i) & PAL (50i) modes)
Note:
Perform these adjustments of all in NTSC (60i) mode first, and
then perform these adjustments of all in PAL (50i) mode.

18-1. Color Reproduction Adjustment ND OFF

Adjust the hue and gain of R-Y and B-Y signals so that proper
color reproduction is produced when the ND filter switch is "OFF".
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note1: The data of page: 0, address: 10 must be "00".
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
2)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
3)
FOCUS .................................................................. MANUAL
4)
ZOOM ........................................................................ LEVER
Adjusting method:
Order Page Address Data
1
2
0
01
3
6
01
4
6
9D
5
6
9E
6
6
12
7
6
12
8
9
6
01
10
6
02
Note3: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 Ω.
(When the component video signals are not outputted, connect
the SW terminal (Pin q;) of the COMPONENT connector to
GND.)
Note4: The adjustment data will be automatically input to page: F, address:
38 to 3B, B4 to B7, C0 to C3, DC to DF.
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
Color bar chart
(HD color bar standard picture frame)
COMPONENT connector
Oscilloscope
F
38 to 3B (HD)
B4 to B7 (SD)
C0 to C3 (HD CINE)
DC to DF (SD CINE)
Procedure
Set the color bar chart, and
check the picture frame.
(Refer to "10. Picture Frame
Setting".)
01
Set the data.
4D
Set the data, and press PAUSE
button.
Change the data and set the Y
signal level (A) to 630mV.
(Note3) (Fig. 6-1-12.)
22
Set the data.
80
Set the data.
00
Set the data.
Check that the Y signal level (A)
is 630mV.
61
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note4)
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
6
9D
3
0
01
6-40
A
H
Fig. 6-1-13.
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvr-z1uHvr-z1nHvr-z1eHvr-z1pHvr-z1c

Table of Contents