4. Focus Ring Adjustment (NTSC (60i) mode)

The MR (Magnet resistor) adjustment of the focus ring is carried
out semi-automatically.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value1
Specified Value2
Specified Value3
Note1: The data of page: 0, address: 10 must be "00".
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
NTSC (60i)/PAL (50i) ......................................... NTSC (60i)
Adjusting method:
Order Page Address Data
1
0
01
2
F
70
3
4
6
01
5
6
02
6
F
A6
7
F
A7
8
F
EC
9
F
ED
10
F
EE
11
F
EF
Note3: The adjustment data will be automatically input to page: F, address:
70, A6, A7, EC to EF.
Note4: For the bit values, refer to "6-4. SERVICE MODE", "4-3. 3. Bit
value discrimination".
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
0
01
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
Not required
Adjustment remote commander
F
70, A6, A7, EC to EF
40 to C0
03 to 78
88 to F8
Procedure
01
Set the data.
Set bit6 of the data to "0", and
press PAUSE button. (Note4)
While rotating the focus ring, do
from Step 3 to Step 4.
B1
Set the data, and press PAUSE
button.
Check that the data changes to
"01" within 10 sec. (Note3)
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.

5. Zoom Ring Adjustment (NTSC (60i) mode)

5-1. Zoom Ring Adjustment (1)

The MR (Magnet resistor) adjustment of the zoom ring is carried
out semi-automatically.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value1
Specified Value2
Specified Value3
Note1: The data of page: 0, address: 10 must be "00".
Note2: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
NTSC (60i)/PAL (50i) ......................................... NTSC (60i)
Adjusting method:
Order Page Address Data
1
0
01
2
F
70
3
4
6
01
5
6
02
6
F
A8
7
F
A9
8
F
F0
9
F
F1
10
F
F2
11
F
F3
Note3: The rotating time between TELE end and WIDE end must be 1
sec. or more.
Note4: The adjustment data will be automatically input to page: F, address:
70, A8, A9, F0 to F3.
Note5: For the bit values, refer to "6-4. SERVICE MODE", "4-3. 3. Bit
value discrimination".
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
0
01
6-27
Not required
Adjustment remote commander
F
70, A8, A9, F0 to F3
40 to C0
03 to 78
88 to F8
Procedure
01
Set the data.
Set bit7 of the data to "0", and
press PAUSE button. (Note5)
While shuttling the zoom ring
between TELE end and WIDE
end, do from Step 3 to Step 4.
(Note3)
B3
Set the data, and press PAUSE
button.
Check that the data changes to
"01" within 10 sec. (Note4)
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.