Mr Adjustment (Ntsc (60I) Mode) - Sony HVR-Z1J Service Manual

Digital video camera recorder
Hide thumbs Also See for HVR-Z1J:
Table of Contents

Advertisement

3. MR Adjustment (NTSC (60i) mode)

The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value1
Specified Value2
Specified Value3
Note1: Make the lens horizontal and perform this adjustment.
Note2: Perform this adjustment before "Flange Back Adjustment".
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
NTSC (60i)/PAL (50i) ......................................... NTSC (60i)
Adjusting method:
Order Page Address Data
1
0
01
2
F
70
3
6
01
4
6
02
5
F
71
6
F
72
7
F
73
8
F
74
9
F
75
10
F
76
11
F
77
12
F
78
13
F
79
14
F
7A
15
F
7B
16
F
7C
Note5: The adjustment data will be automatically input to page: F, address:
70 to 7C.
Note6: For the bit values, refer to "6-4. SERVICE MODE", "4-3. 3. Bit
value discrimination".
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
Not required
Adjustment remote commander
F
70 to 7C
40 to C0
03 to 78
88 to F8
Procedure
01
Set the data.
Set bit2 and bit3 of the data to
"0", and press PAUSE button.
(Note6)
BD
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note5)
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 1.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Check that the data satisfies the
specified value 2.
Check that the data satisfies the
specified value 3.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
0
01
3
6-26
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
Turn off the power and turn on
again.