Before Placing Tumble Dryer Into Service - ALLIANCE BA120E Installation Manual

Tumble dryers
Table of Contents

Advertisement

Installation
4
1. Auxiliary Alarm Fast-On Connection (there is a plastic
shield over the control board that must be tipped down to
access this connection)
2. Test Button
3. Light
4. Reset Button
Before Placing Tumble Dryer into
Service
1. Ensure all panels and guards are in place.
2. Remove and discard wire tie from the airflow switch so it can
swing freely.
3. Pull out emergency stop button, if applicable.
4. Turn on electrical supply to tumble dryer.
5. Open the supply valve for gas or steam heated tumble dryers.
6. After performing the previous checks, start the tumble dryer
by pressing START. (Refer to the Operating section for de-
tailed instructions.) Release the start button and open the
loading door. The cylinder should stop rotating within seven
seconds after the door is opened a maximum of 0.79 inches
[20 mm]. If it does not, adjust the loading door switch. Refer
to Adjustments section.
7. Gas Tumble Dryers: Start the tumble dryer and check the
burner flame. Adjust the air inlet shutter as required. Refer to
Adjustments section.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
3
2
TMB2452N_SVG1
Figure 5
IMPORTANT: The electronic ignition system will at-
tempt to light the gas by sparking for the "trial for
ignition" period. If gas does not ignite within this
period, the ignition control will go into a safety lock-
out and the valve will no longer open until the con-
trol is reset. On CSA models, the electronic ignition
1
system is automatically reset. On AGA and IEC
models the electronic ignition system must be man-
ually reset. The control will pause the cycle and in-
dicate that the ignition control needs to be reset. To
reset the ignition control, press start key on the
control. The control will then prompt for the start
key to be pressed again to restart the cycle. On all
models, ignition lockout may occur due to air in the
gas line or the gas shut-off valve being in the OFF
position. If the air is bled out of the gas line, the gas
shut-off valve is in the ON position, the gas service
is properly connected and the tumble dryer contin-
ues to have heater errors and/or prompts for the ig-
nition control to be reset, remove the tumble dryer
from service.
8. Load the cylinder with a full load of clean rags and run to re-
move oil or dirt from cylinder.
9. Check the airflow switch operation by opening the lint panel;
be sure to remove shipping wire tie from airflow switch prior
to operation. Temporarily tape down the lint panel safety
switch located behind the upper left corner of the lint panel.
The heating systems should shut off when the lint panel is
opened a maximum of 6.0 inches [152 mm] .
The airflow switch operation may be affected by shipping wire
tie still in place, lack of make-up air, or an obstruction in the ex-
haust duct. These should be checked. If there is a problem, con-
tact an authorized service person.
IMPORTANT: Remove tape from the lint panel safety
switch before proceeding to the next step.
Do not operate tumble dryer if airflow switch is
faulty. An explosive gas mixture could collect in
tumble dryer if airflow switch does not operate
properly.
10. Clean cylinder by running a load of wet rags on one maxi-
mum heat cycle.
28
WARNING
W407R1
Part No. 70532501ENR7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga120eHa120nHu120lPk120nNk120nSj120e ... Show all

Table of Contents