CYBEX XP4040 Installer/User Manual page 120

Xp4000 series switch
Table of Contents

Advertisement

To Override Switch Settings One at a Time
1. Referring to Appendix D, determine how you want your switches set.
2. Write down on a piece of paper how you want the switch set. Write a 1 for
a switch that is ON and 0 for a switch that is OFF.
3. Use the command, <CM> SW+<Enter> to enable virtual switching.
4. To turn a switch ON, use the command <CM> SWn=1<Enter> and replace
n with the switch number 1-8.
To turn a switch OFF, use the command <CM> SWn=0<Enter> and replace
n with the switch number 1-8.
Below is a command summary for virtual switching.
<CM>SW= nn <Enter>
<CM>SW n =1<Enter>
<CM>SWn=0<Enter>
<CM>SW+<Enter>
<CM>SW-<Enter>
Overrides DIP switch settings on XPAC/XPAB computer
interface modules. Sets the bank of switches (1-8) to a user
specified ON/OFF combination. To determine the correct DIP
switch code for your system ( nn ), refer to Appendix H.
Overrides DIP switch ( n ) and sets it to the ON position.
Overrides DIP switch ( n ) and sets it to the OFF position.
Enables override of DIP switch settings.
Disables override of DIP switch settings.
114

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp4010Xp4080Xp4400

Table of Contents