9
System Control
& Maintenance
Advanced Operations
The following commands are used for system control and maintenance. Enter
the command sequences to perform the actions described in the table below.
Key Sequence
<CM>RESET<Enter>
<CM>RESETAddr<Enter>
<CM>OFF<Enter>
<CM>M+<Enter>
<CM>SAVE<Enter>
<CM>SW=nn<Enter>
<CM>SWn=1<Enter>
<CM>SWn=0<Enter>
<CM>SW+<Enter>
<CM>SW-<Enter>
<CM>CHASSIS=n<Enter>
<CM>SUN=n<Enter>
<CM>SUNI=n<Enter>
Action
Resets the active user module.
Resets any module in the system, computer or user.
Replace Addr with the address of the module to reset.
Logs a secondary user off of the XP4000 system. User
screen goes blank. Video channel is freed up for other users
in the system. Selecting a channel re-enables the user.
Re-enables the mouse on the current active channel. Use
after switching the type of mouse connected to a user
station, or after the RESET command has been used on
the active computer interface module.
Saves user console configuration (i.e. Swap Mode, Follow
Mode) settings to permanent memory. Any configuration
changes that are not saved will not be retained after a
power reset.
Overrides DIP switch settings on XPAC/XPAB computer
interface modules. Sets the bank of switches (1-8) to a user
specified ON/OFF combination. To determine the correct
DIP switch code for your system (n), refer to Appendix G.
Further instructions can be found on page 113.
Overrides DIP switch (n) and sets it to the ON position.
Overrides DIP switch (n) and sets it to the OFF position.
Enables override of DIP switch settings.
Disables override of DIP switch settings.
Changes the unit address of the local unit to n (0-254).
Non-US Sun Workstations Only Sets all XPAC/XPAB
computer interface modules attached to Suns to emulate
country-specific key codes. To determine the correct code
for your system (n), refer to your Sun workstation
documentation and Appendix H.
Non-US Sun Workstations Only Sets the current XPAC/
XPAB computer interface module (Sun only) to emulate
country-specific key codes. To determine the correct code
for your system (n), refer to your Sun workstation
documentation and Appendix H.