System Configuration
This option allows the administrator to configure a variety of system functions
described below.
Chassis Number
If you do not have an intelligent power supply or a transmitter module in your
unit, use this option to configure your unit's chassis address. Chassis addresses
are numeric, and may be any value between 1 and 254. Unit addresses of "0" and
"255" are reserved. Enter a unique chassis address for this unit.
If you already have a chassis number assigned to this unit, leave the value in this
field at "0". This does not indicate a chassis address of "0." It means only that
the XPDU module will not attempt to give the unit a chassis number.
Command Key Sequence
Use the space bar to toggle though the available key sequences for bringing up
the Command Line Menu. Choose from Numlock -, Numlock *, Numlock +,
Numlock / or Ctrl ~.
Menu Activation Key Sequence
Use the space bar to toggle through the available key sequences for activating
the on-screen menu system. Choose from Ctrl-Ctrl, Alt-Alt or Shift-Shift.
Remote Commands
This option either enables or disables your XPDUs ability to accept remote
commands. Use the space bar to select your choice. For more information on
remote commands, see the section, "User Controls Menu (User Level Access)".
Remap WIN95 Keys
This option is used to determine whether the XPDU module will remap
Windows 95 keys when a Macintosh computer is selected. When enabled, the
Windows keys function as the Mac's Alt/Option keys. The Alt keys function as
the Command/Apple keys. Use the space bar to enable or disable this option.
Stand alone RSP
If you are using a Cybex RSP Commander and have a Macintosh or Sun
keyboard, use the space bar to enable this option.
Follow/Swap Feature Status
Use the space bar to enable Follow mode and Swap mode or to disable either
process. If you are enabling an option, also enter the user address you are
following or swapping with. For more information on Follow or Swap mode,
see Chapter 7, 'Basic Operations.'
Note: You must be logged on as the administrator for this feature to be operational.
Dual Monitor Support Card Address
If your system is configured for dual monitor support, use this option to specify
the address of the XPLU user module that serves as the second monitor in the
dual monitor system. If the field is left blank, dual monitor support is disabled.
See the section "Dual Monitor Support" in this chapter.