[215] Outgoing Message Time
Description
Sets the maximum allowable recording time for outgoing messages (OGM).
This programming is available for the KX-TD1232 only.
Selection
Time (seconds): 0 / 16 / 32 / 64 (0=no recording)
Default
32, 0, 32, 0 (for OGM 1 through 4 from left to right)
Programming
1.
Enter 215.
Display: 215 OGM MSG TIME
2.
Press NEXT to program the time for OGM 1.
Display example: OGM:32, 0,32, 0
3.
Keep pressing SELECT until the desired selection is displayed.
4.
Press
5.
Keep pressing SELECT until the desired selection is displayed.
6.
Repeat steps 4 and 5 to program the time for OGM's 3 and 4.
7.
Press STORE.
8.
Press END.
Conditions
• There are three messages available:
OGM 1:
used for DISA (Direct Inward System Access) message 1 or UCD (Uniform Call
Distribution) message 1
OGM 2:
used for DISA message 2 or UCD message 2
OGM 3:
used for Timed Reminder or UCD message 3
OGM 4:
used for UCD message 4
• Enter the times starting from the left for OGM 1 to OGM 4.
• The total time of the outgoing messages cannot exceed 64 seconds.
Programming Guide
to program the time for OGM 2.
General Programming
139