Outgoing Message Time - Panasonic KX-TD1232 Program Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD1232:
Table of Contents

Advertisement

[215] Outgoing Message Time

Description
Sets the maximum allowable recording time for outgoing messages (OGM).
This programming is available for the KX-TD1232 only.
Selection
Time (seconds): 0 / 16 / 32 / 64 (0=no recording)
Default
32, 0, 32, 0 (for OGM 1 through 4 from left to right)
Programming
1.
Enter 215.
Display: 215 OGM MSG TIME
2.
Press NEXT to program the time for OGM 1.
Display example: OGM:32, 0,32, 0
3.
Keep pressing SELECT until the desired selection is displayed.
4.
Press
5.
Keep pressing SELECT until the desired selection is displayed.
6.
Repeat steps 4 and 5 to program the time for OGM's 3 and 4.
7.
Press STORE.
8.
Press END.
Conditions
• There are three messages available:
OGM 1:
used for DISA (Direct Inward System Access) message 1 or UCD (Uniform Call
Distribution) message 1
OGM 2:
used for DISA message 2 or UCD message 2
OGM 3:
used for Timed Reminder or UCD message 3
OGM 4:
used for UCD message 4
• Enter the times starting from the left for OGM 1 to OGM 4.
• The total time of the outgoing messages cannot exceed 64 seconds.
Programming Guide
to program the time for OGM 2.
General Programming
139

Advertisement

Table of Contents
loading

This manual is also suitable for:

Td1232Kx-td816Td816

Table of Contents