Viewing Live Camera Images

Setting up monitor output

1. Press the [MENU] button.
• The [MENU] → [DETAIL OPERATION] → [MONITOR]
screens will be displayed in this sequence in accordance
with the [MENU Screen Operations] explained on page 17.
MONITOR
BORDER COLOR
AUTO CHANGE ..
SPLIT PICTURE ..
BLIND CAMERA ..
CAMERA TITLE ..
ALARM REC DISP
VGA OUT
2. Select your desired item with the [ / ] keys, and then
change the value of the setting with [–/+].
Settings
BORDER COLOR
Sets the brightness of the border lines for split screen displays.
BLACK/DARK GRAY/GRAY/LIGHT GRAY
* The brightness of the border lines for spot output will also
change at the same time.
ALARM REC DISP
Sets the camera input to display when an alarm is detected.
OFF:
Does not change the display
FIXED:
Displays the camera input started with the most
recent alarm recording. When alarm recording is
started for multiple camera inputs simultaneously,
each of these are displayed for a period of one
second, and then the camera input with the small
number will be displayed.

SEQUENTIAL:

Displays all of the camera inputs sequentially for a
period of one second each during alarm recording.
VGA OUT
DISABLE: Does not output images from VGA OUT.
ENABLE: Outputs images from VGA OUT.
3. Press the [SET] button.
• The confirmation screen will be displayed.
4. Select [SAVE] with the [ / ] keys, and then press
[SET].
24
LIGHTGRAY
2.
OFF
ENABLE
SEQUENTIAL
1. Press the [MENU] button.
• The [MENU] → [DETAIL OPERATION] → [MONITOR]
screens will be displayed in this sequence in accordance
with the [MENU Screen Operations] explained on page 17.
SEQUENCIAL
CAMERA 1
CAMERA 2
CAMERA 3
CAMERA 4
CAMERA 5
CAMERA 6
CAMERA 7
CAMERA 8
CAMERA 9
SPLIT PICTURE
2. Select your desired item with the [ / ] keys, and then
change the value of the setting with [–/+].
Settings
CAMERA 1 to 9
Sets the time at which each screen is to be switched.
1 SEC, 2 SECS, 3 SECS, 5 SECS, 10 SECS:
Sequential display is carried out in accordance with
the time set.
OFF:
Sequential display not performed.
SPLIT PICTURE
1 SEC, 2 SECS, 3 SECS, 5 SECS, 10 SECS:
Sequential display is carried out in accordance with
the time set.
3. Press the [SET] button.
• The confirmation screen will be displayed.
4. Select [SAVE] with the [ / ] keys, and then press
[SET].
* Depending on the monitor being used, there are cases
where images will be distorted for a short period of time
when switching between screens when display is being
carried out in the QUAD PICTURE sequential mode.
1 SEC
1 SEC
1 SEC
1 SEC
1 SEC
2.
1 SEC
1 SEC
1 SEC
1 SEC
1 SEC

Advertisement