JVC VR-509E Instructions Manual page 14

Jvc digital video recorder instructions
Hide thumbs Also See for VR-509E:
Table of Contents

Advertisement

Getting Started
Part Names and Functions (Signal I/O Terminals) (continued)
Terminal
[ALARM IN]
Alarm Input
[EMERGENCY]
Emergency Input
[EXT REC IN]
External Record Input
[CLOCK RST IN]
Clock Reset Input
[CLOCK RST OUT]
Clock Reset Output
[ALARM RESET]
Alarm Reset Input
[REC OUT]
Record Status Output
[WARNING OUT]
Warning Output
[OPE ON/OFF]
Operate ON/OFF
[SPOT 1 · 2]
Spot Output Selection
14
min.400 ms
* Set the output impedance to 10kΩ or less
min.400 ms
* Set the output impedance to 10kΩ or less
About 1 s
min.400 ms
* Set the output impedance to 10kΩ or less
REC STOP
WARNING
About 1 s
Switches to OFF when [OPERATE] is set at ON.
Switches to ON when [OPERATE] is set at OFF.
The SPOT output more is selected in accordance with a combined
input of [SPOT 1·2] Make/Open. (Page 26)
Signal Level
External pull-up level
External pull-up level
External pull-up level
Remarks
Make Contact Input
Make Contact Input
Open collector
(DC15V, 10mA or
less)
Make Contact Input
Open collector
(DC15V, 10mA or
less)
Open collector
(DC15V, 10mA or
less)
Make Contact Input
Make Contact Input

Advertisement

Table of Contents
loading