Table 5-2: Auto Migration Troubleshooting
Error Message
The new target array has an earlier firmware
version than the source array
The type of interface boards in the target
array is incorrect
The number of interface boards in the target
array is incorrect
The bandwidth of interface boards in the
target array is insufficient
An incorrect array is connected
Failure has occurred in the source array
Failure has occurred in the target array
Intermittent failure has occurred in the
source array
Failure has occurred in the source array
Unexpected error has occurred
Disconnect the target array as described below and start
it in normal mode to upgrade the firmware to the same
or later version as the source array. Then try the auto
migration again.
Visit the Hitachi Web Portal at http://support.hds.com.
Visit the Hitachi Web Portal at http://support.hds.com.
Visit the Hitachi Web Portal at http://support.hds.com.
Visit the Hitachi Web Portal at http://support.hds.com.
Shut down and restart the source array. Restart the
source array. When the Ready LED goes ON, perform
the migration again. If the Ready LED does not go ON,
visit the Hitachi Web Portal at http://support.hds.com.
Shut down and restart the source array. It is possible to
use the source array after reboot. If the problem
persists, visit the Hitachi Web Portal at
support.hds.com
Click Switch Array in the Array Migration window.
The data shredding operation has failed. Return the
source array, without trying to shred the data.
Visit the Hitachi Web Portal at http://support.hds.com.
Troubleshooting
Hitachi Simple Modular Storage 100 User's Guide
Suggested Actions
http://
to obtain a target array.
5–11
Need help?
Do you have a question about the Simple Modular Storage 100 and is the answer not in the manual?
Questions and answers