Hitachi 2000 Series Hardware Reference Manual

High-performance nas platform
Table of Contents

Advertisement

Hitachi High-performance NAS Platform
Hardware Reference
Release 8.2
MK-99BA012-13

Advertisement

Table of Contents
loading

Summary of Contents for Hitachi 2000 Series

  • Page 1 Hitachi High-performance NAS Platform Hardware Reference Release 8.2 MK-99BA012-13...
  • Page 2 Hitachi, Ltd. Hitachi, Ltd., reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. This document contains the most current information available at the time of publication.
  • Page 3 Notice Hitachi Data Systems products and services can be ordered only under the terms and conditions of Hitachi Data Systems’ applicable agreements. The use of Hitachi Data Systems products is governed by the terms of your agreements with Hitachi Data Systems.
  • Page 4 Revision 4, replaces and supersedes MK-96BA001-03. MK-99BA012-12 February 2012 Revision 5, replaces and supersedes MK-96BA001-04. MK-99BA012-13 April 2014 Revision 6, replaces and supersedes MK-99BA012-12. Contact Hitachi Data Systems 2845 Lafayette Street Santa Clara, California 95050-2627 https://portal.hds.com North America: 1-800-446-0744 Hitachi High-performance NAS Platform...
  • Page 5: Table Of Contents

    Hitachi High-performance NAS Platform™ Components ... . . 9 Introducing the Hitachi High-performance NAS Platform™ ....9 Ventilation .
  • Page 6 Powering Down the High-performance NAS Platform for Shipment or Storage . . 39 Powering On a Hitachi High-performance NAS Platform™/Cluster ... . . 39 Management Interfaces ........41 RS-232 Serial Management Port .
  • Page 7: Safety Information

    • Do not remove more than one unit at a time. • Hitachi Data Systems recommends that the stabilizer plate be secured to the front of the system cabinet. For more information, see "Attaching the Stabilizer Plate to the System Cabinet,"...
  • Page 8: Electrical Precautions

    If a module is faulty, replace it with one of the same type, of at least the same capacity and speed. • Always shut down a High-performance NAS Platform before it is moved, switched OFF, or reset. • Maintain backup routines. viii Hitachi High-performance NAS Platform...
  • Page 9: Mandatory Regulations

    Safety Information • The SFPs approved for use with supported storage enclosures vary depending on the original manufacturer of the unit. SFPs qualified for older systems might not be approved for use with the most current storage systems. To ensure proper operation of the High-performance NAS Platform and the storage subsystems, use only the approved replacement parts for each system, which can be purchased by contacting your sales representative.
  • Page 10: Canadian Department Of Communication Compliance Statement

    Radio Protection for Germany Dieses Gerät erfüllt die Bedingungen der EN 55022 Klasse A. Food and Drug Administration (FDA) The product complies with FDA 21 CFR 1040.10 and 1040.11 regulations, which govern the safe use of lasers. Hitachi High-performance NAS Platform...
  • Page 11: Chinese Rohs Compliance Statement For The Hitachi High-Performance Nas Platform

    Safety Information Chinese RoHS Compliance Statement for the Hitachi High-performance NAS Platform ! ! ! ! ! ! ! ! ! ! Toxic and Hazardous Substances Table ! ! ! ! ! ! ! ! ! ! ! Toxic and Hazardous Substances and Elements...
  • Page 12 Hitachi High-performance NAS Platform...
  • Page 13: About This Manual

    This manual is designed for administrators who are responsible for the network storage in an organization. The following types of messages are used throughout this manual. Hitachi Data Systems recommends that these icons and messages are read and clearly understood before proceeding: Tip: A tip contains supplementary information that is useful in completing a task.
  • Page 14 De volgende pictogrammen worden in de hele handleiding gebruikt in het belang van de veiligheid. We raden u aan alle procedure-informatie die door deze pictogrammen wordt gemarkeerd, aandachtig te lezen en ervoor te zorgen dat u de betreffende procedure goed begrijpt vóór u verder gaat. Hitachi High-performance NAS Platform...
  • Page 15 About This Manual VOORZICHTIG: “Voorzichtig” geeft aan dat er risico op schade aan data of apparatuur bestaat. We raden u aan even halt te houden bij de sectie die door dit woord wordt gemarkeerd, tot u de procedure volledig begrijpt. WAARSCHUWING: Een waarschuwing wijst op een mogelijk gevaar voor de persoonlijke veiligheid.
  • Page 16: Other Useful Publications

    • Hitachi High-performance NAS Platform System Installation Guide: In PDF format, this guide provides information about installing hardware, software and firmware, including instructions on how to upgrade and downgrade the Hitachi High-performance NAS Platform and the SMU. • Hitachi High-performance NAS Platform Command Line Reference: This guide (in HTML format) describes how to administer the system by typing commands at a command prompt.
  • Page 17: System Cabinet And Components

    The system is housed in a 42U high cabinet. A U is a unit of measurement equivalent to 1.75 inches or 44.45 millimeters. The main components are: • Hitachi High-performance NAS Platform The system can contain a single High-performance NAS Platform, or several High- performance NAS Platforms operating as a cluster. Clusters using more than two High-performance NAS Platforms typically include 2 x 10Gbps Ethernet switches (one is required, but two are recommended for redundancy).
  • Page 18 Fibre Channel (FC) switches The High-performance NAS Platform supports Fibre Channel switches that connect multiple servers and storage subsystems. Contact Hitachi Data Systems Technical Resource Center (TRC) for information about which Fibre Channel switches are supported. • 10 GbE (10 Gigabit Ethernet) switches (used in cluster configurations only) The High-performance NAS Platform supports 10 GbE switches that connect multiple servers when configuring a cluster.
  • Page 19: Server Specifications

    20 ports. This switch allows you to create a cluster with up to 8 nodes. Hitachi Data Systems requires dual 10 GbE switches for redundancy. In a dual- switch configuration, if one switch fails, the cluster nodes remain connected through the second switch.
  • Page 20: Attaching The Stabilizer Plate To The System Cabinet

    Attaching the Stabilizer Plate to the System Cabinet The stabilizer plate and mounting hardware are supplied with the 19-inch rack. Note: To ensure the stability of the cabinet once it has been loaded, Hitachi Data Systems recommends attaching the stabilizer plate to the rack before loading the cabinet.
  • Page 21: Hitachi High-Performance Nas Platform Components

    For more information, see "Replacing System Components," on page The following tables show which modules are compatible with which models of High- performance NAS Platform: Table 1: Series 2000 Hitachi High-performance NAS Platform Modules Model 2000/2000R Model 2100 Model 2200...
  • Page 22: Ventilation

    The system has been shut down. Flashes once every three seconds. Flash (0.8Hz) The High-performance NAS Platform is available to host file services but is not cur- rently doing so. Flash (5Hz) The High-performance NAS Platform is rebooting. The High-performance NAS Platform is not powered up. Hitachi High-performance NAS Platform...
  • Page 23: Rear Panel

    Hitachi High-performance NAS Platform Components Table 4: Status LED (Amber) State Meaning Amber Critical failure and the High-performance NAS Platform is not operational. Slow Flash System shutdown has failed. Flashes once every three seconds. Flash (0.8Hz) The High-performance NAS Platform needs attention, and a non-critical failure has been detected.
  • Page 24 High-performance NAS Platform Rear Panel (Series 2000) High-performance NAS Platform Rear LEDs (Series 3000) Hitachi High-performance NAS Platform...
  • Page 25: Nim1045

    Hitachi High-performance NAS Platform Components High-performance NAS Platform Rear LEDs (Series 2000) Note: Depending on the model of your High-performance NAS Platform, the number and type of Ethernet ports on the NIM module may be different than shown above. Table 5: Module Status LED (Green/Amber)
  • Page 26: Nim1050/Nim1060

    NIM1050/NIM1060 Table 8: Gigabit Ethernet (GE) Ports Status/Activity (Per Port) Meaning Status Green 1 Gbps link present (On, not flashing) Green Flash (1.25 Hz) 1 Gbps link standby in a redundant configuration Green Off No link Hitachi High-performance NAS Platform...
  • Page 27: Nim1200

    Hitachi High-performance NAS Platform Components Table 8: Gigabit Ethernet (GE) Ports (continued) Status/Activity (Per Port) Meaning Activity Amber Flash Network activity Amber Off No Network activity For information about the serial (RS-232) port, see "RS-232 Serial Management Port," on page...
  • Page 28: Fsa20Xx/Fsx20Xx

    The FSA and FSX modules have only one LED, which is the Module Status LED. Table 12: FSA/FSX Module Status LED State Meaning No power. Green Normal operation. Flash Green (5 Hz) Board is booting, running self-test or resetting. Amber Critical fault with the module (hardware). Hitachi High-performance NAS Platform...
  • Page 29: Fsb302X

    5.2, and you must configure that module with the second stage loader (SSLoader) version from SU 6.0 (or above). Note, however, that the NIM, FSA, and SIM modules in the server can run older versions of SSLoader. Refer to the Hitachi High- performance NAS Platform System Installation Guide for instructions on using SSLoader.
  • Page 30: Sim41Xx

    Amber Off No network activity Note: For FSB303x modules, the High Speed Interface operates in an Active/Active mode and network activity related to connectivity may show on one or both ports at any given time. SIM41xx Hitachi High-performance NAS Platform...
  • Page 31: Sim4322

    Hitachi High-performance NAS Platform Components Table 16: Fibre Channel Ports Status/Activity (Per Port) Meaning Status Green 2 or 4 Gbps FC link present (On, not flashing) Green Off No link Activity Amber Flash Network activity Amber Off No network activity...
  • Page 32: Sim4324

    SIM4324 Table 19: Fibre Channel Ports Status/Activity (Per Port) Meaning Status Green 2 or 4 Gbps FC link present (On, not flashing) Green Off No link Activity Amber Flash Network activity Amber Off No network activity Hitachi High-performance NAS Platform...
  • Page 33: Power Supply Unit (Psu600/Psu610)

    If the battery in a PSU model 600 fails, the entire PSU should be replaced, and the failed unit must be disposed of responsibly. Contact Hitachi Data Systems Technical Resource Center (TRC) for more information on disposing of a PSU. PSU model 610 contains a field-replaceable battery.
  • Page 34: Psu And Battery Care

    PSU. The original PSU should be returned to the repair depot for service. PSU610 modules have field replaceable battery packs. Contact Hitachi Data Systems Technical Resource Center (TRC) to request a replacement battery pack. When received, follow the instructions below to replace the old battery pack.
  • Page 35 Hitachi High-performance NAS Platform Components 1. Remove the five countersunk screws and one pan-head screw that hold the access cover. Carefully set aside the fasteners for later reassembly. 2. Slide off the cover, and remove the battery pack from the PSU case.
  • Page 36 8. Realign the access cover with the mounting holes, and install the five countersunk screws on the front and side of the PSU. Fasten them snugly but do not overtighten. 9. Reinstall the pan-head screw through the rear panel of the PSU and into the access cover. Fasten snugly. Hitachi High-performance NAS Platform...
  • Page 37: Replacing System Components

    NAS Platform. NIM, FSA, FSB, FSX, and SIM modules are not hot- swappable components. See "Rebooting, Shutting Down, and Powering Off the Hitachi High-performance NAS Platform™," on page 37 for information on how to power down a server. Replacing a Hitachi High-performance NAS Platform...
  • Page 38: Upgrading A Sever/Cluster By Replacing Modules

    Upgrading a Series 2000 Hitachi High-performance NAS Platform to Series 3000 To upgrade a Series 2000 Hitachi High-performance NAS Platform™ to a Series 3000: 1. Back up the server configuration (registry). Using Web Manager, log in to the server/cluster node to be upgraded, and select Server Admin >...
  • Page 39: Replacing A Nim 1060 With A Nim 1200

    3, you must load the most current firmware package via the SSLoader. If it is necessary to reload software, reload the complete software image file (do not strip unused files). Refer to the Hitachi High-performance NAS Platform System Installation Guide for instructions on using SSLoader and loading the software.
  • Page 40: Replacing A Nim 1060 With A Nim 1200 In A Single/Standalone Server

    SSLoader is installed on the NIM 1200. If there is no SSLoader on the new NIM 1200, you must upload it manually using Xmodem before it is possible to boot the server. Refer to the Hitachi High-performance NAS Platform System Installation Guide for instructions on using SSLoader.
  • Page 41 This will display the console, which you can use to enter CLI commands on the server to complete the following steps. Refer to the Hitachi High-performance NAS Platform Command Line Reference for more information on the commands used below.
  • Page 42: Replacing A Nim1060 With A Nim1200 Module In Cluster Nodes

    SSLoader. To make the server boot again, it will be necessary to upload the SSLoader onto the new NIM module using the serial connection or Xmodem. Refer to the Hitachi High-performance NAS Platform System Installation Guide for instructions on using SSLoader.
  • Page 43 EVS-to-server mapping. 6. Replace the NIM 1060 with the NIM 1200. "Replacing a Hitachi High-performance NAS Platform™ Module (Non- Upgrade)," on page 25 for details. 7. Restore the physical network connections.
  • Page 44: Replacing An Fsa Module With An Fsx Module

    SSLoader. To make the server boot again, it will be necessary to upload the SSLoader onto the new NIM 1200 using a serial connection or Xmodem. Refer to the Hitachi High-performance NAS Platform System Installation Guide for instructions on using SSLoader.
  • Page 45: Replacement Procedure

    If your FSX is an FSX2034-1, the minimum supported software revision is SU 5.2, and you must configure that module with the SSLoader version from SU 6.0 (or above). Refer to the Hitachi High-performance NAS Platform System Installation Guide for instructions on using SSLoader.
  • Page 46 Start uploading the new package to the server by entering the following command: ssc laptop_IP_address package-upgrade package_name where laptop_IP_address is the IP address you set (in step 2-b) and package_name is the software package to upload. Hitachi High-performance NAS Platform...
  • Page 47: Replacing A Psu

    If the firmware package is still not listed, or the package fails validation, attempt to reload the firmware package again (see step 12) or call Hitachi Data Systems Technical Resource Center (TRC). 14. Perform a final reboot to ensure the latest SSLoader is running. See Step 2 (above) for instructions on checking the SSLoader version.
  • Page 48: Replacing A Fan Assembly

    Caution: If a fan has failed, replace the fan assembly as soon as possible to avoid damaging the High-performance NAS Platform. Replacing a Fan Assembly 1. Remove the High-performance NAS Platform front panel by releasing the two latches (one each side). Hitachi High-performance NAS Platform...
  • Page 49: Rebooting, Shutting Down, And Powering Off The Hitachi High-Performance Nas Platform

    6. When the connector is firmly in place, secure the module with the captive screws which were previously loosened. 7. Replace the front panel. Rebooting, Shutting Down, and Powering Off the Hitachi High-performance NAS Platform This section provides instructions on how to reboot, shut down, and power off a server or cluster.
  • Page 50: Powering Down The High-Performance Nas Platform For Maintenance

    3. To turn off the System Management Unit (SMU), depress the red button located on the right of the unit. 4. Power off the storage subsystems, beginning with the enclosures that house the RAID controllers. 5. Power off the expansion enclosures for the storage subsystems. Hitachi High-performance NAS Platform...
  • Page 51: Powering Down The High-Performance Nas Platform For Shipment Or Storage

    PSU modules from the chassis. For long term storage of PSU spares, contact a support representative at Hitachi Data Systems. When the system is shutdown under normal circumstances, depending on the battery charge level, the battery can last from 1 to 6 months.
  • Page 52 "Power Supply Unit (PSU600/PSU610)," on page 21 for more information on the PSUs in a High-performance NAS Platform. 5. If you are starting a cluster, wait 5-10 seconds before switching the power to "on" for the next node in the cluster. Hitachi High-performance NAS Platform...
  • Page 53: Management Interfaces

    Management Interfaces Management Interfaces The High-performance NAS Platform offers two types of physical management ports: • RS-232 Serial (DB-9) • Switched 10BaseT/100BaseTX Ethernet High-performance NAS Platform Management Interfaces (Series 3000) High-performance NAS Platform Management Interfaces (Series 2000) All management ports are physically located on the NIM, and provide connections to ports within the High-performance NAS Platform cabinet only.
  • Page 54: Rs-232 Serial Management Port

    SMU and use SSH to access the server's CLI. Table 22: Host Setting Values Terminal Requirement Connection Crossover (nullmodem) cable Protocol Asynchronous RS-232 Baud rate 115,200 Bps Data bits Stop bits Parity None Flow control None Hitachi High-performance NAS Platform...
  • Page 55 Management Interfaces The table below shows the pin layout for serial port 1. Table 23: Serial Port 1 Pin Layout Pin Positions Signal Abbreviation Data Carrier Detected Receive Data Transmit Data Data Terminal Ready Signal Ground Data Set Ready Request To Send Clear To Send Ring Indicator Hardware Reference...
  • Page 56 Hitachi High-performance NAS Platform...
  • Page 57 Hitachi High-performance NAS Platform Hardware Reference...
  • Page 58: Contact

    Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California 95050-2639 U.S.A. www.hds.com Regional Contact Information Americas +1 408 970 1000 info@hds.com Europe, Middle East, and Africa +44 (0)1753 618000 info.emea@hds.com Asia Pacific +852 3189 7900 hds.marketing.apac@hds.com MK-99BA012-13...