HP 5800-48G Installation Manual page 30

5820x & 5800 switch series
Hide thumbs Also See for 5800-48G:
Table of Contents

Advertisement

slowly along the guide rails into the slot until it has firm contact with the connectors on the
backplane.
To prevent damage to the connectors inside the switch chassis, insert the power supply gently. If
you cannot insert the power supply into the slot, re-orient the power supply rather than use
excessive force to push it in.
4.
If only one power supply is installed, install a power filler module in the empty power supply slot
for good ventilation of the switch, as shown in
Figure 29 Installing a power supply
Figure 30 Installing a power filler module
Removing a power supply
CAUTION:
If the switch has two power supplies, removing one power supply does not affect the operation of the
switch. If the switch has only one power supply, removing the power supply powers off the switch.
To remove a 650 W AC power supply, 300 W AC power supply, 650 W DC power supply, or 300 W
DC power supply from a 5800AF-48G or 5820AF-24XG switch:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is correctly grounded.
2.
Squeeze the tabs on the power cord connector with your thumb and forefinger, and pull the
connector out to remove the power cord, as shown in
3.
Hold the handle on the power supply with one hand, pivot the latch on the power supply to the
right with your thumb, and pull the power supply part way out of the slot, as shown in
Supporting the power supply bottom with one hand, slowly pull the power supply out with the other
4.
hand.
5.
Put away the removed power supply in an antistatic bag for future use.
Figure
30.
Figure
24
31.
Figure
32.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents