HP 5800-48G Installation Manual: Connecting The Switch To A 12 Vdc Output Rps

Hp 5820x & 5800 switch series installation guide.
Hide thumbs

Advertisement

Figure 38 Connecting the switch to a –54 VDC output RPS

Connecting the switch to a 12 VDC output RPS

This section applies to the 5800-48G (1 slot), 5800-48G TAA (1 slot), 5800-24G, and 5800-24G TAA
switches.
To connect these switches to the RPS that provides 12 VDC output:
1.
Loosen the captive screws on the RPS receptacle and remove the cover, as shown in
Put away the cover and re-install it after you remove the RPS DC-input power connector.
2.
Unpack the RPS power cord, identify the plug for connecting to the switch, correctly orient the plug
with the RPS receptacle on the switch chassis, and insert the plug into the receptacle (see callout 1
in
Figure
If you cannot insert the plug into the receptacle, re-orient the plug rather than use excessive force
to push it in.
3.
Tighten the screws on the plug with a flat-blade screwdriver to secure the plug in the power
receptacle (see callout 2 in
4.
Connect the other end of the power cord to the RPS.
Figure 39 Removing the cover over the RPS receptacle
40).
Figure
2
40).
30
1
Figure
39.