6. Mechanical adjustment
[1]
<C>
<D>
10. Feed out the test copy and check if there is any folding deviation.
46
9. Move the two positioning dowels [1]
[1]
to adjust.
A0D6F3C513DA
• If it is deviated downward <C>, move
the positioning dowel to the left.
• If it is deviated upward <D>, move the
positioning dowel to the right.
NOTE
• Only the folding line will move.
4583F3C524DA
Field Service Ver. 2.0 Jan. 2008