Scanning Active Time - Datalogic Powerscan PD7100 Product Reference Manual

Industrial corded handheld linear imager bar code reader
Hide thumbs Also See for Powerscan PD7100:
Table of Contents

Advertisement

Scanning Active Time

This setting specifies the amount of time that the reader stays in scan ON state once the
state is entered. The range for this setting is from 1 to 255 seconds in 1-second incre-
ments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 =
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING.
5. Scan the appropriate three digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
This completes the procedure. See
Table 4. Scanning Active Time Setting Examples
STEP
ACTION
1
Desired Setting
2
Pad leading zero(es)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT SCANNING ACTIVE TIME SETTING
Scan Three Characters From
5
Appendix E, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
005, 20 = 020, etc.
ming Mode.
resent the duration which was determined in the steps above. You will hear a two-
beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
ming Mode.
1 Second
001
'0', '0' and '1'
Table 4
for some examples of how to set this feature.
EXAMPLES
90 Sec. (1.5 min.) 180 Sec. (3 min.) 255 Seconds (4.25 min.)
090
180
'0', '9' and '0'
'1', '8' and '0'
Scanning Features
Appendix E,
Keypad, that rep-
255
'2', '5' and '5'
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents