Ack Nak Timeout Value - Datalogic Powerscan PD7100 Product Reference Manual

Industrial corded handheld linear imager bar code reader
Hide thumbs Also See for Powerscan PD7100:
Table of Contents

Advertisement

RS-232/USB-Com Interfaces

ACK NAK Timeout Value

This option specifies the amount of time the reader waits for an ACK character from
the host following label transmission. The selectable timeout range is 200 millisec-
onds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the
timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
This completes the procedure. See
feature.
Table 10. ACK NAK Timeout Value Setting Examples
STEP
ACTION
1
Desired Setting
2
Divide by 200
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
Scan Two Characters From
5
Appendix E, Keypad
7
Scan ENTER/EXIT PROGRAMMING MODE
60
with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
ming Mode.
resent the duration which was determined in the steps above. You will hear a two-
beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
ming Mode.
200ms
01
'0' and '1'
Appendix E, Keypad
for some examples of how to set this
Table 10
EXAMPLES
1,000ms (1 sec.) 5200ms (5.2 sec.)
05
26
'0' and '5'
'2' and '6'
PowerScan
, that rep-
15,000ms (1 sec.)
75
'7' and '5'
TM
PD7100 Corded

Hide quick links: