Symbologies
MSI — cont.

MSI Set Length 1

This feature specifies one of the barcode lengths for
minimum label length if in
Length
The length can be set from 01 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 0 to 50). Pad the number with leading
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
3. Scan the barcode: SELECT MSI LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in the Keypad Appendix, that represent
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See the table below for some examples of how to set this
feature.
Table 37. MSI Length 1 Setting Examples
STEP
ACTION
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT MSI LENGTH 1 SETTING
Scan Two Characters From the
4
Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
290
Variable Length
Mode. Length includes the barcode's data characters only.
zeroes to yield two digits. For example: 1 = 01, 5 = 05, 20 = 20, etc.
Mode.
the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
Mode.
01 Characters
'0' and '1'
MSI Length Control
Mode, or the first fixed length if in
EXAMPLES
07 Characters
15 Characters
'0' and '7'
'1' and '5'
PowerScan
. Length 1 is the
Fixed
50 Characters
'5' AND '0'
TM