Plessey Decoding Level - Datalogic Powerscan PD7100 Product Reference Manual

Industrial corded handheld linear imager bar code reader
Hide thumbs Also See for Powerscan PD7100:
Table of Contents

Advertisement

Plessey — cont.

Plessey Decoding Level

Decoding Levels are used to configure a barcode symbology decoder to be very aggressive
to very conservative depending on a particular customer's needs.
There are many factors that determine when to change the decoding level for a particular
symbology. These factors include spots, voids, non-uniform bar/space widths, damaged
labels, etc. that may be experienced in some barcode labels. If there are many hard to read
or damaged labels that cannot be decoded using a conservative setting, increase the de-
coding level to be more aggressive. If the majority of labels are very good quality labels,
or there is a need to decrease the possibility of a decoder error, lower the decoding level
to a more conservative level.
Plessey Decoding Level = 1
Product Reference Guide
Choosing Level 1 results in a very conservative decoder at the expense of not being able to
read poorly printed or damaged labels.
Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows
decoding of poorly printed and damaged labels at the expense of increasing the likelihood
of decoding errors.
Choosing Level 3, which is the default setting, allows the majority of product labels to be
decoded.
ENTER/EXIT PROGRAMMING MODE
Plessey Decoding Level = Disable
Plessey Decoding Level = 2
Plessey
305