Stand Mode Illumination Off Time; Scanning Active Time - Datalogic QuickScan QM24 Series Product Reference Manual

General purpose handheld area imager bar code reader
Hide thumbs Also See for QuickScan QM24 Series:
Table of Contents

Advertisement

Reading Parameters

Stand Mode Illumination Off Time

Specifies the amount of time reader illumination stays off after pulling the trigger when in Stand
Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 sec-
onds). See
page 255
$CSNTM
Select Stand Mode Time Setting

Scanning Active Time

This setting specifies the amount of time that the reader stays in scan ON state once the state is
entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See
page 256
in "References" for further description of this feature.
$CSNET05(CR)
Scanning Active Time = 5 seconds
Product Reference Guide
in "References" for a description of this feature.
DEFAULT
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
Appendix D, Keypad
acters in
desired character(s). End by scanning the ENTER/EXIT
bar code again.
04 = 2 Seconds
$CSNET03(CR)
Scanning Active Time = 3 seconds
$CSNET08(CR)
Scanning Active Time = 8 seconds
Enter/Exit Programming Mode