Dsp Sis Commands For Mix-Point Level And Mute Control - Extron electronics DMP 128 User Manual

Digital matrix processor
Hide thumbs Also See for DMP 128:
Table of Contents

Advertisement

DsP sis commands for Mix-point Level and Mute control

Many functions; gain, mute, group masters, mix-points, and a protected configuration can
be controlled using SIS commands. These commands follow the same general rules as
basic SIS commands, but the variables ( X/ ) tend to be more complex. Before attempting
SIS control of the DSP, a comprehensive understanding of the audio signal flow is helpful
to understanding the commands. Figure 96 shows the specific DSP functions available for
SIS command control of the mix-points.
notE: This supplement refers only to the mix-point and corresponding level and
Outputs
Inputs
Virtual Returns
Expansion Inputs
Figure 96.
The Mix Matrix mix-points addressed by this section are:
a
b
c
Setting the level of a single mix-point in the mix matrix requires an SIS command that
contains both the mix-point location and level. Making or breaking a connection between
a mix-point input and output requires the mix-point location be unmuted or muted.
mute control commands. See
commands and functions.
Output
Mix Matrix
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1 - 8
1
2
3
4
5
6
7
9 - 16
DSP Processors Addressable via SIS Commands
Output Mix Matrix (including level and mute)
Virtual Send Mix Matrix (including level and mute)
Expansion Output Mix Matrix (including level and mute)
DSP SIS Commands
Virtual Send
Expansion Output
Mix Matrix
Mix Matrix
8
Virtual Send Bus
Expansion Outputs
8
A
B
C
D
E
F
G
H
1
2
3
4
5
6
7
8
Expansion Outputs
9
10
11
12
13
14
15
16
8
A
B
C
D
E
F
G
H
DMP 128 • Reference Information
on page 141 for basic SIS
170

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmp 128 atDmp 128 c p at

Table of Contents