Download Print this page

Cabling And Features; Control - Serial (Com) - Extron electronics IPCP 505 Setup Manual

Control processor integrates ethernet connection into av systems
Hide thumbs Also See for IPCP 505:

Advertisement

IPCP 505 • Setup Guide (Continued)

Cabling and Features

Attach cables using the following wiring diagrams as a guide. Full details are available in the IPCP 505 User Guide.
ATTENTION:
Installation and service must be performed by authorized personnel only.
Power
• Connect to 110 to
240 VAC.
100-240V
50-60Hz
1
2
+ - + -
SWITCHED 12VDC
40W MAX TOTAL
3
4
+ - + -
5A MAX
Rear Panel
Control — Serial (COM)
Rear Panel
100-240V
50-60Hz
1
2
COM1
+ - + -
TX RX G
SWITCHED 12VDC
40W MAX TOTAL
AL
3
4 4
COM4
+ - + -
TX RX G
5A MAX
5A
To COM7,
COM8
Heat Shrink
Over Shield Wires
To COM1
- COM6
NOTE: If you use cable that has a drain wire, tie the drain wire to ground at both ends.
2
Power Input
• Front panel LED lights when
the IPCP receives power.
Switched 12 VDC
Power Output
• 12 VDC, 40 watts (max.)
= total output for all four ports
combined
• Corresponding front panel
green LEDs (
) light when
power is available at each port.
3/16"
(5 mm)
Max.
Tie Wrap
COM2
COM3
COM7
COM1 - COM6
TX RX
G
TX RX
G
TX RX
G
RTS
CTS
COM7, COM8
COM5
COM6
COM8
(RS-232, RS-422, RS-485)
TX RX
G
TX RX
G
TX RX
G
RTS
CTS
NOTE: The 5-pole COM ports support both
CTS
Clear to send
RTS
Request to send
G
Ground
Rx Receive
Tx
Transmit
G
Ground
Rx
Receive
Tx
Transmit
IPCP 505
SWITCHED
12VDC
1
R
3
Front Panel
Serial (COM) Ports
Select protocol via software or
SIS command.
(RS-232)
COM 1-8 port default protocol:
• 9600 baud
• 8 data bits • 1 stop bit
• no parity
• no flow control
hardware and software flow control.
The 3-pole COM ports support software
flow control.
Projector, Panel
Display, PC, or Other
RS-232, RS-422, or
Transmit (Tx)
RS-485 Device
Receive (Rx)
Heat Shrink
RS-232-
Transmit (Tx)
Controllable
Receive (Rx)
Device
Strip wires 3/16"
(5 mm) max.
Lights if total power draw is
40-44 watts.
2
LIMIT
T
T T
R
R R
4
OVER
Lights if total power draw
exceeds 44 watts.
Power output shuts off.
The user must turn these
ports back on.
Front Panel
COM
H
H H ED
C
LIMIT
TX
RX
OVER
1
2
3
4
RTS = Request to Send
CTS = Clear to Send
Tx = Transmitting Data
Rx = Receiving Data
COM7, COM8 Pin Configurations
Pin
RS-232
RS-422
1 (Tx)
Tx
Tx-
2 (Rx)
Rx
Rx-
3 (G)
Ground
Ground
4 (RTS)
RTS
Tx+
5 (CTS)
CTS
Rx+
RTS
CTS
TX
RX
5
6
7
8
RS-485
Data-
(pins 1 & 2
tied together)
Ground
Data+
(pins 4 & 5
tied together)

Advertisement

loading