Usb Configuration Port (Front Panel); Front Panel Indicators - Extron electronics DMP 128 User Manual

Digital matrix processor
Hide thumbs Also See for DMP 128:
Table of Contents

Advertisement

usB configuration Port (Front Panel)

A front panel configuration port uses an Extron USB A Male to USB Mini B Male
Configuration Cable, 26-654-06 for connection to a PC computer USB port.
The USB 2.0 port uses a mini type-B connector to connect to a host computer for
control. The DMP 128 USB driver must be installed prior to using the port (see
the USB Driver
notE: The DMP 128 appears as a USB peripheral with bi-directional

Front Panel indicators

a
Ç É
ACTIVITY
EXP
CONFIG
a
b
c
d
on page 15).
communication. The USB connection is used for software operation (see
Windows-based Program Control
Programming and Control
c
INPUTS
1
2
3
4
5
6
7
CLIP
LAN
SIGNAL
Figure 7.
DmP 128 Front Panel
Power LED — The power indicator blinks during power-up and firmware uploads,
and lights solid when the DMP 128 is operational.
Activity Indicators — Two green LEDs labeled EXP (
É
and LAN (
) for the standard Ethernet port
Ç
(non-AT models)
Off — The unit is not connected to a second DMP 128.
On — The unit is connected to another DMP 128 and configured as the primary
unit.
Blinking — The unit is connected to another DMP 128 and is currently
configured as the secondary unit.
Ç
(AT models)
Off — Dante device is not responding.
On — The EXP port is connected to a non-AT DMP 128 and configured as the
primary unit.
Blinking — The EXP port is not connected.
É
Indicates activity on the corresponding rear panel Ethernet port connection.
Input Indicators — Stacked red (signal clipping) and green (signal present) LEDs for
inputs 1 through 12 . Each stack represents one input channel.
The green signal LED varies in brightness corresponding to the real-time input or
output signal level (see item d , below). It begins to light at – 60 dBFS increasing
in steps to full intensity as the signal level increases. When the signal level reaches
– 3 dBFS or above, the red clipping LED lights and remains lit as long as the signal
remains above – 3 dBFS. When it falls below that level, the red LED remains lit for 200
milliseconds, after which the display resumes real-time monitoring of the signal level.
Output Indicators — Stacked red (signal clipping) and green (signal present) LEDs
for outputs 1 through 8. Each LED stack represents one output channel.
on page 13), and SIS control (see
on page 129).
d
OUTPUTS
8
9
10
11
12
1
2
3
4
5
6
7
8
CLIP
SIGNAL
DMP 128 • Installation and Operation
Installing
SIS
DMP 128
DIGITAL MATRIX PROCESSOR
Ç
) for the expansion audio port
9

Advertisement

Table of Contents