Pitney Bowes DM100i Series Service Manual & Parts List page 53

Pitney bowes dm100i/dm200i series mailing system service manual & parts list
Hide thumbs Also See for DM100i Series:
Table of Contents

Advertisement

2529
Unknown component ID in the print zone packed byte parameter
252A
Unknown function ID in the print zone packed byte parameter
252B
Message resent maximum number of times without response
252C
Trouble retrieving a test print from FLASH
252D
Current account has expired during a mail run
252E
Error while preparing the trusted SW key
252F
Unknown device ID found in a tealeaves table
2530
Department account does not have enough funds
2531
Department account has reached allowed mailpieces
2532
Unknown department account Error
2533
Error while getting info from an installed type "Misc" graphic
2534
Error while getting info from an installed Swiss star
2535
Error accessing a required Entgelt Bezahlt in flash
2536
Error while trying to get bar code parameters from FLASH
2537
Error while trying to get NPCG.BIN from external flash
2538
Error while trying to get xxxPCG.BIN from external flash
2539
Error while trying to get PRINTEST.BIN from external flash
253A
Gate keeper model is unknown
253B
Snippet handler was unable to retrieve a snippet from FLASH
253C
iButton® PSD communications driver, success but no expected event
253D
iButton® PSD communications driver, failure miscellaneous
253E
Error while accessing a miscellaneous graphic in the flash
253F
Error creating dynamic blob for image generator
2540
Error creating static blob for image generator
2541
Error creating report blob for image generator
2542
Error logging postage value download message to shadow log
2543
Error logging debit certificate to shadow log
2544
iButton® PSD communications driver, success but timeout error
2545
iButton® PSD communications driver, failure OS no event match error
2546
iButton® PSD communications driver, failure OS timeout error
2547
SCM_CURRENCY_MISMATCH, Currency code mismatch between indicia graphic and psd
2548
SCM_CMOS_GMTOFFSET_OUT_OF_RANGE, CMOS gmtGMToffset out of range, reset to defaults
2549
SCM_PERMIT_NOT_FOUND, Error accessing a permit graphic
254A
SCM_DATETIME_NOT_FOUND, Error accessing a date time graphic
254B
SCM_PERMIT_BATCH_COUNT_SET_ERROR, Error setting permit batch count index
254C
Error finding an auto inscription in flash
254D
Auto inscription ID is not in range
254E
Piece count end of life error
254F
Failure to correct shadow log
2550
Error logging postage value refund message to shadow log
2551
Error in fnValidData, probably a missing table entry
2552
Error in fnWriteData, probably a missing table entry
SDT345A DM100i/DM200i Service Manual & Parts List
Table 4-15 DM100i/DM200i BOB Task errors (25xx) continued
4 • Troubleshooting
4-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dm200i series

Table of Contents