3. Installation,
continued
Wiring the Inverter AC Input (refer to diagrams on the following pages) Remove the chassis AC
access cover to access the internal terminal block.
Route the cable and conduit from the main panel, approved bypass selector switch or main
AC panel to the inverter's AC INPUT conduit clamp. Tighten
the clamp securely on the conduit. Always leave a little extra slack in the wiring.
Connect the hot wire (BLACK) from the main panel's dedicated 30 amp breaker to the
"AC INPU T (HOT 1 IN)" terminal. Tighten the screw terminal to 16 inch-p o u n d s .
NOTE: If using dual inputs, connect the RED wire from the main panel to AC INPUT
(HOT 2 IN)
Connect the neutral (WHITE) from the main panel's neutral bus bar to the "AC
INPUT (NEU)" terminal. Tighten the screw terminal to 16 inch-p o u n d s .
Connect the ground (GREEN) wire from the main panel's neutral bus bar to the "GROUND"
terminal. Tighten the terminal to 16 inch-p o u n d s .
Wiring the Inverter AC Output (refer to diagrams on the following pages) Route the cable and
conduit from the AC distribution panel to the inverter's AC OUTPUT conduit clamp.
Tighten the clamp securely on the conduit.
Connect the hot (BLACK) wire to the "AC OUTPUT 1 (HOT)" terminal. Tighten the
terminal to 16 inch-pounds.
NOTE: If using dual outputs, connect the RED wire to the "AC OUTPUT 2 (HOT)"
terminal.
Connect the neutral (White) wire to the "AC OUTPUT (NEU)" terminal. Tighten the
terminal to 16 inch-pounds.
Connect the ground (Green) wire to the "GROUND" termin a l . T i g h t e n t h e t e r m i nal to
16 inch-pounds.

Final Inspection

Verify all cables / conduit runs are secured with wire ties or other nonconductive
fasteners to prevent chafing or damage from movement and vibration.
Verify strain reliefs or grommets are in place to prevent damage to the wiring or conduit where it
passes through walls, bulkheads or other openings.
V e r i f y a l l A C c o n n e c t i o n s a r e c o r r e c t a n d t o r q u e d t o 1 6 i n c h p o u n d s .
Replace the covers on the main electrical / distribution panel. Replace
t h e chassis access cover.
Verify the inverter's front panel switch is in the "OFF" position.
NOTE: If required by code, have the installation inspected by an electrical inspector.