4. Troubleshooting and Specifications

Low Battery –
The unit has shut down because the battery voltage is below the set
point in LBCO. It will automatically restart when battery
voltage rises above 12.5 VDC.
High Battery –
The unit has shut down because the battery voltage has exceeded 15.5
VDC. It will automatically restart when the battery voltage drops below
15.5 VDC.
Overtemp –
The unit has shut down because the temperature at the transformer or FET
board has exceed the safe temperature operating range. It will
automatically restart after unit cools down.
AC Overload –
The unit has shut down because the AC load connected to the inverter's
output exceeded its maximum output rating.
NOTE: When this occurs, reduce the load and MANUALLY
restart the unit.
Specifications
Electrical Requirements 12 VDC
Controls
LED Indicators
Soft Keys
Selector Switch
Display
Cable type
Weight
Dimensions
Cutout Dimensions
Specifications at 25 °C - subject to change without notice.
2003 - Magnum Energy, Inc.
Ó
Charger (ON/OFF),
Inverter (ON/OFF)
Power, Fault, Charger, Inverter
Shore, AGS, Meter, Setup, Tech
Rotary (press to accept)
LCD (2 line)
4 wire twisted pair
0.5 lb (0.22 kg)
3.75" H x 5.75" W x 1.125" D
(9.5 cm H x 16.6 cm W x 2.9 cm D)
2.75" H x 4.75" W (7 cm
H x 12 cm W)
Fault Conditions