Soft Keys, continued:
Setup –
Configures the inverter/charg er. Options include:
Search
Used to set the search watts at which the inverter will come out of "sleep"
mode. Selections are 3-75 watts.
LBCO (Low Battery Cut Out)
Used to set the DC voltage level to shut down the inverter and protect the
batteries from over-discharge damage. Selections are 9.0 VDC, 10.0
VDC and 11.0 VDC. DC volts must reach and maintain LBCO
setting for 1 minute before inverter shut down is initiated.
Battery Size
Used to select the approximate battery bank capacity. Selections are in 200
amp increments from 200 -1000 amps. Battery capacity is also used to
determine absorption time during battery charging. See Chart 2.
Battery Charge Rate
Used to set the maximum charge rate during bulk, absorption or float
charge. Selections are in 10 amp increments from 10% - 100%.
Battery Type
Used to select battery type for the battery charge profile. Selections are
Gel, AGM (Absorbed Glass Mat), Liquid Lead Acid (Flooded) and
Custom (future). See Chart 1.
C o n t r a s t
U s e d t o a d j u s t t h e L C D c o n t r a s t .
AC Dropout Voltage
Used to select the AC voltage threshold (60, 90, 100 VAC) where the
inverter transfers from AC line to inverter mode.
Tech – (display only)
Reserved for future, this feature is used for troubleshooting the
inverter/charger. Options in clude FET temp, transformer temp, and
battery temp.
Factory Reset
Restores all settings to factory defaults. press and hold the switch the switch
for 5 seconds. "Reset Complete" will be appear in the display. See Chart 3.