LEDs

The remote contains the following LEDs to indicate various
modes of operation.
PWR (green):
OFF - NO AC power from inverter, shore or generator at
inverter output terminals
ON - AC power available from inverter, shore or generator at
inverter output terminals
FAULT (red):
OFF - Normal operation
ON - Inverter or Charger shutdown from: Overtemperature (check tech
menu for exact cause), Low Battery Voltage (battery voltage
below LBCO setting or lower than 9.0 VDC, High Battery
Voltage (above 15.5 VDC), AC Overload (loads larger than
i n v o u t p u t c a p a c i t y )
C H G ( g r e e n )
OFF - Charger OFF, no shore or generator AC present
Fast Blink - AC present from shore or generator, synchroniz ing
to AC waveform before relay transfer
ON - Bulk, Absorb, Float ,Equalize or Battery Full Charge
mode
Slow Blink - Charger Standby (Charger off button was pressed with AC
available from shore or generator), Charger Backoff (charger
temperature too hot and charger automatically reduced charge rate to
maintain temperature), Low AC Input Voltage (Input voltage below 85 VAC.
Charger automatically disabled to help stabilize AC line voltage).
INV (green)
OFF - Inverter OFF
Slow Blink - Search Mode. AC load below the Search Watts setting
ON - Inverter ON and s upplying AC to output terminals
NOTE: When both the INV and CHG LEDs are "ON," the Inverter
is in standby mode. Shore or generator AC power is passed through the
inverter to the loads. If shore or generator power is lost, the inverter
automatically supplie s A C power to the loads.