Float –
At the end of absorption time, the charger reduces the charge voltage to
the float voltage setting for the battery type selected. See Chart 1.
TM
Battery Saver
- "Battery Full"
Battery saver mode is a new and unique setting to Magnum Energy's
inverter/chargers. It maintains the batteries without "overcharging" thus
preventing excessive loss of water in flooded batteries or drying
out of AGM batteries. After 4 hours in float mode, the charger is
switched OFF and "Battery Full" is indicated. When the battery voltage
drops to 12.9 VDC, the charger turns on and float charges the batteries to a
nominal level. Once that level has been reached, the charger returns to
"Battery Full" mode to monitor the batteries.
Equalize –
The battery charger is delivering equalize voltage to the
batteries for a maximum of 4 hours. See Chart 1. Press and hold the switch
down for 5 seconds to initiate EQ. The LED will blink fast.
NOTE: Equalize mode will not start until the charger is in float
or "Full Battery" mode.