Table 2-3, Ac Input/Output Wiring Confi Gurations - Magnum Energy MS Series Owner's Manual

Ms series pure sine wave inverter/charger
Hide thumbs Also See for MS Series:
Table of Contents

Advertisement

Installation
2.5.5
AC Wiring Confi gurations
The following table provides the different wiring confi gurations for installing and connecting the
AC conductors into and out of the inverter (refer to fi gures 2-11 to 2-15 for installation drawings
showing these confi gurations).
Table 2-3, AC Input/Output Wiring Confi gurations
SI/SO
(30A)
Single In/
Single Out
(30A)
AC Source
120 VAC @
1
Required
< 30 amps
Reason to
Have an 120
Use
VAC source
that is < 30
amps.
Requires
a separate
inverter
sub-panel.
Appropriate
MS2012
Models
MS2812
MS4024
Maximum
30A
Input
(single pole)
Breaker
-
Required
#10 AWG
-
(In & Out)
Minimum
Wire Size
Maximum
3600W
Inverter
(30A @
Pass-thru
120 VAC)
capacity
Wiring
Figure 2-11
Diagram
Note 1: AC Source is from either the utility/grid power (i.e., shore power) or an AC generator.
Note 2: If 2 legs of 30A @ 120 VAC are used, they must be from the same source.
Page 24
SI/SO (60A)
SI/DO
Single In/
Single In/
Single Out
Dual Out
(60A)
120 VAC @
120/240 VAC (or
> 30 amps
2 separate legs of
(60 amps
120 VAC)
@ < 15 amps per
maximum).
leg (-15B models);
or < 20 amps per
leg (-20B models).
Have an 120
Do not want to
VAC source
install a separate
that is > 30
inverter sub-panel.
amps.
Inverter pass-thru
Requires
capability limited
a separate
by model used:
inverter
-15B = 30 amps;
sub-panel.
-20B = 40 amps.
MS2012
MS2012-20B
MS2812
MS2012-15B
MS4024
60A
-15B models:
(single pole)
30A (single pole);
-
-20B models:
#6 AWG
40A (single pole)
(In & Out);
Can be split to
#10 AWG (In)
two #10 AWG
(Hot input must
(for HOT 1
be split to two
& HOT 2)
#12 AWG);
#12 AWG x2 (Out)
7200W
-15B models:
(60A @
3600W
120 VAC)
(30A @ 120 VAC);
-20B models:
4800W
(40A @ 120 VAC);
Figure 2-12
Figure 2-13
DI/SO
Dual In/
Single Out
120/240 VAC (or
2 separate legs
of 120 VAC)
@ < 30 amps
per leg
Want dedicated
charging and
dedicated pass-
thru while the
AC source is on.
Requires a
separate inverter
sub-panel.
MS2012
MS2812
MS4024
30A
(dual pole)
-
#10 AWG
-
(In & Out)
3600W
(30A @
120 VAC)
Figure 2-14
© 2009 Magnum Energy Inc
DI/DO
Dual In/
Dual Out
120/240 VAC (or
2 separate legs
of 120 VAC)
@ < 30 amps per
leg
May need to
power 240 VAC
loads when
AC source is
on (requires
120/240 VAC
source).
Requires a
separate inverter
sub-panel.
MS2012
MS2812
MS4024
30A
(dual pole)
-
#10 AWG
(In & Out)
7200W
(2 legs of 30A @
120/240 VAC or
2 legs of 30A @
120 VAC)
2
Figure 2-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnasine ms2012Magnasine ms2812Magnasine ms4024

Table of Contents