Use a utility knife or sharp chisel to cut temp sensor loose then
2.7.c
clean remaining silicon from transformer
2.7.d Remove 4 corner Phillips head screws holding down transformer
2.7.e
Install new transformer being careful to align #10 nylon shoulder washers
into base while setting transformer in place. Make sure to install
from transformer to correct terminal on ac board or damage will occur
to FET board when ac power is applied
2.7.f
Install 4 screws with nylon shoulder washers and tighten snug
2.7.g Use silicon to glue down sensors to transformer in old location. Use tape
to temporarily hold sensors until silicon dries
2.7.h Reinstall Top Cover