wires can lead to instant FET board failure upon connecting ac
power to the unit.
WIRING COLOR CODE:
White – Neutral
Black – AC Hot
2 Blue – Hot
IN
2.2.e Install wires to new ac board and install 4- #6 x ½ Torx screws.
2.2.f
Use silicon to glue down sensors to transformer in old location. Use tape
to temporarily hold sensors until silicon dries.
2.2.g Re-install Top Cover
(2 wires)
IN
1 Red – Hot
IN
2
OUT