Configuring the Inverter

The ME Series inverter/charger must be configured for Low Battery Cutoff (LBCO),
Shore Power Current, Charger Amps, Battery Size and Battery Type. These
operational parameters must be configured using the optional remote control.
Refer to the ME Series Remote Control operator's manual to configure the following
parameters:
Shore (5, 10, 15, 20, 30, 50)
AGS OFF
Enable
Meter DC
A C
Setup Search
LBCO
Battery Bank
Battery Type
Charge Rate
Contrast
Factory Reset
Tech Temps Fault
Record
The ME Series inverter/charger also allows you to select an equalize charge for
the batteries. Press and hold the Charger ON/OFF switch for 4 seconds. The Equalize (EQ) function will
be initiated (and the correct code will be sent to the remote.) The EQ function
automatically terminates after 4 hours of operation. You can also manually stop the
equalize mode by pressing and holding the Charger ON/OFF switch while the inverter is in
EQ mode.