Installation
2.5.6
AC Wiring Confi guration
The following table provides the different wiring confi gurations for installing and connecting the
AC conductors into and out of the inverters (see Figures 2-11 to 2-14 for installation diagrams
showing these confi gurations).
Table 2-3, AC Input/Output Wiring Confi gurations
SI/SO
(30A)
Single In/
Single Out
(30A)
AC Source
120 VAC @
1
Required
< 30 amps
Reason to
Have an 120
Use
VAC source
that is < 30
amps.
Requires
a separate
inverter
sub-panel.
Appropriate
RD2212
Models
RD1824
RD2824
RD3924
Maximum
30A
Input
(single pole)
Breaker
-
Required
#10 AWG
-
(In & Out)
Minimum
Wire Size
Maximum
3600W
Inverter
(30A @
Pass-thru
120 VAC)
capacity
Wiring
Figure 2-11
Diagram
Note 1: AC Source is from either utility power or a generator.
Note 2: If two legs of 30A @ 120 VAC are used, they must be from the same source.
Page 23
SI/SO (60A)
DI/SO
Single In/
Dual In/
Single Out
Single Out
(60A)
120 VAC @
120/240 VAC (or
> 30 amps
2 separate legs
of 120 VAC)
(60 amps
@ < 30 amps
maximum).
per leg
Have an 120
Want dedicated
VAC source
charging and
that is > 30
dedicated pass-
amps.
thru while the
Requires
AC source is on.
a separate
Requires a
inverter
separate inverter
sub-panel.
sub-panel.
RD2212
RD2212
RD1824
RD1824
RD2824
RD2824
RD3924
RD3924
60A
30A
(single pole)
(dual pole)
-
#6 AWG
#10 AWG
(In & Out);
(In & Out)
Can be split to
two #10 AWG
(for HOT 1
& HOT 2)
7200W
3600W
(60A @
(30A @
120 VAC)
120 VAC)
Figure 2-12
Figure 2-13
DI/DO
Dual In/
Dual Out
120/240 VAC (or
2 separate legs
of 120 VAC)
@ < 30 amps per
leg
May need to
power 240 VAC
loads when
AC source is
on (requires
120/240 VAC
source).
Requires a
separate inverter
sub-panel.
RD2212
RD1824
RD2824
RD3924
30A
(dual pole)
-
-
#10 AWG
(In & Out)
7200W
(2 legs of 30A @
120/240 VAC or
2 legs of 30A @
120 VAC)
Figure 2-14
© 2010 Magnum Energy, Inc