FLUE AND BAROMETRIC DAMPER CONNECTION

Before connecting the stove pipe, make sure you have removed the accessories
from the flue pipe as the scraper, shovel and the poker.
The flue outlet on the Caddy furnace is 6" in diameter and the wood only or wood/electric models may be installed
with a 6" chimney approved for use with wood burning heating appliances (2100°F). However, we recommend the
use of a 7" chimney to allow the retrofit to wood/oil configuration, if desired, without changing the chimney; in that
case, a 6" to 7" reducer must be installed at the flue outlet of the furnace. If the draft exceed -0.06 w.c., a barometric
control must installed.(see Damper) Never install a manual damper.
UH-CADDY PIPE
(OPTION)
REDUCER
DIAMETER 7 "
For a proper installation, follow the advices below:
1. All the evacuation pipe joints must be secured with three screws.
Make sure that each screw goes through the inner walls of both connectors (male and female).
See pictures below showing a male-female coupling.
PROPER INSTALLATION
IMPROPER INSTALLATION
CAUSE RESTRICTION
2. A minimum rise of 1/4 inch per horizontal foot must be respected.