COMBUSTION SAFETY CONTROL

The AFG type oil burner is equipped with an electronic control (# R7184B1032) including a pre-purge
function and a new more durable drive motor.
PRE-PURGE
When there is a call for heat, the burner's fan will run for 15 seconds before the actual ignition takes place
to vent the combustion chamber and generate a proper draft. This will result in a smoother ignition of the oil
burner.
SAFE OPERATION
If the flame goes out while the burner is running, the CAD cell will detect it; the control will then switch to
the "RECYCLE" mode and cut the fuel supply to the burner for 60 seconds. After this delay, the control
goes back to "IGNITION" mode. If the flame goes out 3 times in a row, the control will switch to the
"LOCKOUT" mode to prevent a continuous cycling of the ignition process, which would cause a premature
sooting of the combustion chamber and smoke pipe. To deactivate the "LOCKOUT" mode, press and hold
the reset button of the control for 30 seconds.
A green diagnostic LED on the control has four states:
-
On = Flame present
-
Off = No flame
-
2 seconds On, 2 seconds Off = "Recycle" mode
-
1/2 second On, 1/2 second Off = "Lockout" mode TEMPORARY SHUT-OFF
By pressing and holding the reset button, the burner will shut-off until the reset button is released. When
the button is released, the control will start over at the beginning of the normal cycle.
FOR ADDITIONAL INFORMATIONS ON OPERATION SEQUENCES OF THE BURNER, CONSULT THE
BURNER INSTRUCTION MANUAL.

COMBUSTION ADJUSTMENT AND VERIFICATION

To enjoy the efficiency of our oil burning units, you must respect the following criterias:
TOOLS REQUIRED:
-
DRAFT GAUGE
-
SMOKE TESTER
-
PUMP PRESSURE GAUGE
-
NOZZLE AND ELECTRODES POSITION TESTER
-
COMBUSTION TESTER
CHECK LIST:
-
SELECTION OF NOZZLE AND HEAD
-
NOZZLE / ELECTRODES POSITION IN RELATION TO THE HEAD
-
PUMP PRESSURE
-
OIL LINE IS BLEED
-
LOW FIRING RATE BAFFLE (INSIDE THE BURNER) REQUIRED ON UH-CADDY.
-
FAN SPEED
-
BAROMETRIC DAMPER POSITION
30