Smoke Detector; Door Glass; Glass Specifications; Ash Drawer - PSG 15 Kw Installation And Operating Instructions Manual

Wood and combined 15 kw, 18 kw, 20 kw, 25 kw and uh-caddy
Table of Contents

Advertisement

SMOKE DETECTOR

We highly recommend the use of a smoke detector. It must be installed at least 15 feet (4,57 m) from the
appliance in order to prevent undue triggering of the detector when reloading.

DOOR GLASS

To maintain a clean and safe installation, do not build your fire too close to the glass or allow the fire logs to lean
on the glass.
Do not operate your furnace at too low a setting. Keep the air inlet opened long enough during the fire start-up to
prevent the fire from smouldering, which could stain the glass.
An intense fire will help keeping the glass clean. However, in the event that your glass gets stained, which should
normally not occur, you will have to clean it using a wet cloth and an oven cleaner. Cleaned the glass ONLY when
the unit has cooled down. Do not use abrasive cleanser. Wood stove glass cleaners are available on the market
and their efficiency makes no doubt.
WARNING: Avoid knocking or scratching the glass which could crack or break.

GLASS SPECIFICATIONS

The glass is made of Pyroceram type of glass, 3/16" – (5 mm) thick.
Do not operate your furnace with a broken glass, as this could seriously damage your furnace.
You can purchase a replacement glass from your PSG dealer.

ASH DRAWER

Your furnace is equipped with an ash drawer to collect ashes produced by the combustion of wood. This drawer
must not be left open during combustion as this may cause over firing and serious damages to the furnace.
The drawer must be cleaned regularly.
It is important that the door and the ash drawer be kept closed while the appliance is in use.
Maintain all gaskets in good condition; in case of deterioration, contact your dealer for replacement
gasket.

ASH GRATE

You must replace the ash grate if it is damaged and a replacement may be obtained from your dealer. The steel
plate on the ash grid is meant to optimize the heat inside the combustion chamber and should only be removed to
empty the ashes.
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

18 kw20 kw25 kwUh-caddyCaddy series

Table of Contents