Key features
Key features of the RPS2-EIF power supply include:
•
•
•
Physical dimensions and weight
Table 25
TABLE 25
Power Supply
RPS2-EIF
Input connector specifications
The following specifications apply to the RPS2-EIF power supply input connector:
•
•
•
Regulatory compliance
This section contains regulatory standards for Brocade power supplies.
Electromagnetic compatibility (EMC) and immunity standards
Brocade power supplies comply with the conducted and radiated test and immunity standards as
listed in
TABLE 26
Power Supply
RPS2-EIF
Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
53-1002187-01
DRAFT: BROCADE CONFIDENTIAL
Operating 90 VAC to 254 VAC input, universal or wide input
Rated 100 to 240 V ~ 50 or 60 Hz
644 Watts of total output power
lists the dimensions and weight of the RPS device.
Physical dimensions and weight of the redundant power supply
Dimensions
1.69 in (H) x 17.32 in (W) x 12.72 in (D)
4.3 cm (H) x 44.0 cm (W) x 32.3 cm (D)
IEC socket 216C743-07
C14 type: UL File No. E29179
CSA File No. LR19980
Table
26. EMC standards are within a 6 dB minimum margin.
EMC and Immunity standards for power supplies
EMC standards
•
ICES-003, Electromagnetic Emission
•
FCC Part 15 Class A
•
EN 55022 or CISPR 22 Class A
•
VCCI Class A
•
EN 61000-3-2, Power Line Harmonics
•
EN 61000-3-3, Voltage Fluctuation & Flicker
•
EN 61000-6-3, Electromagnetic Compatibility,
Generic Standard
•
AS or NZS CISPR 22, Electromagnetic
Compatibility
•
Harmonic Current Emissions (Class A) -
EN61000-3-2, with Amendment 14 (1999)
Redundant power supply specifications
Weight
5.5 kg. (12.1 lb)
Immunity standards
•
EN 61000-6-1, Electromagnetic
Compatibility, Generic Standard
•
EN 55024, Information
Technology equipment -
Immunity Characteristics
7
67