Installing an optional module in the device

FIGURE 23
Follow the steps below to install an optional module into the device.
1. Remove the two mounting screws on the blank metal plate (or a previously installed module)
2. Before opening the package that contains the new module, touch the bag to the device casing
3. Remove the module from the anti-static shielded bag.
4. Holding the module level, guide it into the carrier rails on each side and push it into the slot,
5. When the module has properly engaged the connector, tighten the retainer screws to secure
6. When the device is powered on, the module LED on the device front panel should turn green to
CAUTION
If you do not install a module in a slot, you must keep the slot panel in place. If you run the device
with an uncovered slot, the system will overheat.
Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
53-1002187-01
DRAFT: BROCADE CONFIDENTIAL
Installing an optional module
with a flat-head screwdriver. Remove the old module, or blank plate.
to discharge any potential static electricity. Brocade recommends using an ESD wrist strap
during installation.
until it firmly engages with the connector.
the module in the slot.
confirm that the module is correctly installed and ready to use.