Troubleshooting

Diagnosing device indicators

This chapter describes LED indicators and the steps required to troubleshoot problems.
TABLE 14
Symptom
Power LED is Off
Power LED is Amber
Diag LED is Amber
Link LED is Off
(RPS2-EIF) Link LED is Off
(RPS2-EIF) Link LED is Amber
(RPS2-EIF) Activity LED is Green

Power and cooling problems

If the power indicator does not turn on when the power cable is plugged in, you may have a problem
with the power outlet, power cable, or internal power supply. However, if the unit powers off after
running for a while, check for loose power connections, power losses or surges at the power outlet,
and verify that the fans on the unit are unobstructed and running prior to shutdown. If you still
cannot isolate the problem, the internal power supply may be defective. In this case, contact
Technical Support for assistance.

Installation

Verify that all system components have been properly installed. If one or more components appear
to be malfunctioning (such as the power cable or network cabling), test them in an alternate
environment where you are sure that all the other components are functioning properly.
Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
53-1002187-01
DRAFT: BROCADE CONFIDENTIAL
Troubleshooting chart
Action
Internal power supply is disconnected.
Check connections between the device, the power cable, and the wall
outlet.
Contact Technical Support.
Internal power supply has failed. Contact Technical Support.
The device self test has detected a fault.
Power cycle the device to try and clear the condition. If the condition
persists, contact Technical Support.
Verify that the device and attached device are powered on.
Be sure the cable is plugged into both the device and corresponding
device.
Verify that the proper cable type is used and the length does not exceed
specified limits.
Check the adapter on the attached device and cable connections for
possible defects. Replace the defective adapter or cable if necessary.
The port does not have a valid connection to the device.
Check connections between the device, the power cable, and the wall
outlet.
Primary power supply is active. RPS unit is on standby.
Primary power supply is off. RPS unit is now active