Installing a redundant power supply

Installation

An RPS device may be placed on a desktop or mounted in a rack.
DANGER
DO NOT place an RPS device on the floor as the case is not waterproof. It is recommended that
RPS devices be installed in a network equipment rack.

Selecting a site

RPS2-EIF units can be mounted in a standard 19 inch equipment rack or on a flat surface. When
choosing a location, follow the guidelines below:
Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
53-1002187-01
DRAFT: BROCADE CONFIDENTIAL
RPS2-EIF Status LEDs
Port Indicators
2
RPS2-EIF status LEDs
Condition
Off
On Yellow
Flashing Yellow
Off
Flashing Green
On Green
RPS2-EIF power status LED
Condition
On Green
Off
Installing a redundant power supply
1
2
System Indicators
Status
The port does not have a valid connection to a device.
The port has a valid connection to a device.
There has been a RPS device internal power failure.
The port is not providing power to the connected device.
The port has been shut down due to one of the following conditions:
• The system has detected an over-current condition.
• One or more of the fans have failed.
The port is providing power to a connected device.
Status
AC power is being supplied to the RPS.
No AC power is being supplied to the RPS device.